Automatic Polarimeter / Saccharimeter SAC-i 589/882

High Performance Sugar Analysis, Now Easier Than Ever.


It has become common that dark color - raw sugar samples are measured at 882nm without decolorization treatment.
SAC-i 589/882 can measure samples at both 589nm and 882nm by changing the optical units.

Specifications
Model SAC-i 589/882
Cat.No. 5952
Scale Angle of Rotation,
International Sugar Scale (without temperature compensation),
International Sugar Scale (with Automatic Temperature Compensation)
Measurement Readings Angle of Rotation
International Sugar Scale (without temperature compensation)
International Sugar Scale (with Automatic Temperature Compensation)
Specific Rotation
Concentration
Purity
User scale
Angle of Rotation (Temperature Compensation of Quartz Plate)
Temperature (°C / °F)
Measurement Range Angle of Rotation:-89.9999 to +90.0000° and -360.0000 to +360.0000°
International Sugar Scale : -259.0000 to +259.0000°Z
Resolution Angle of Rotation : 0.0001°
International Sugar Scale : 0.0001°Z
Measurement Accuracy 589nm

①Angle of Rotation:±0.005° (-45.0 to +45.0°)
②International Sugar Scale:±0.015°Z (-130.0 to +130.0°Z)
Other ranges
①Angle of Rotation:±0.010°
②International Sugar Scale:±0.030°Z
* Checked by reading a standard quartz plate

882nm

①Angle of Rotation:±0.005° (-19.3 to +19.3°)
②International Sugar Scale:±0.015°Z (-130.0 to +130.0 °Z)
Other ranges
①Angle of Rotation:±0.010°
②International Sugar Scale:±0.070°Z
* Checked by reading a standard quartz plate
Temperature compensation range 10 to 40℃
Ambient Temperature Use the instrument where the temperature is between 10 to 40°C
Display Panel 7.5 inch color LCD (touch screen)
Temperature display accuracy ±0.2 °C
Light source LED:
589nm interference filter,
882nm interference filter
Prism Glan-Taylor Prism
Measurement Wavelength 589nm (equivalent to the sodium-D line spectrum)
882nm(infrared nearby)
Power Supply AC100 to 240V, 50/60Hz
Included Accessories Software, PolariSoft
Observation tube included Observation tubes (100mm(5mL),200mm(10mL))
Dimensions & Weight 60×36.5×21cm, 20.0kg
Power consumption 140VA
Output terminals Digital Printer DP-63 or
DP-AD (sold separately),
Output method : RS-232C (9 pin D-Sub male connector)
USB flash drive and PC - USB
Options

· Digital Printer DP-63 (Thermal printer) : Cat.No.3118

· Digital printer DP-AD (Dot matrix printer) : Cat.No.3123

· Observation tube 50mm OT-50(I) (SUS) 2.5mL : RE-72080

· Observation tube 100mm OT-100(I) (SUS) 5mL : RE-72078

· Observation tube 200mm OT-200(I) (SUS) 10mL : RE-72079

· Jacketed flow tube with funnel 100mm : RE-72113

· Jacketed flow tube with funnel 200mm : RE-72114

· Unjacketed flow tube with funnel 100mm : RE-72037

· Unjacketed flow tube with funnel 200mm : RE-72038

· Unjacketed small volume observationtube 10mm long : RE-72042

· Jacketed flow tube 50mm(With water jacket) : RE-72110

· Jacketed flow tube 100mm (With water jacket) : RE-72111

· Jacketed flow tube 200mm(With water jacket) : RE-72112

· Quartz control plate 34°(100°Z) : RE-72045

· Quartz control plate 17°(50°Z) : RE-72044

· Quartz control plate 8°(25°Z) : RE-72043

· Quartz Control Plate -34° (-100°Z) : RE-72050

· Quartz Control Plate -17° (-50°Z) : RE-72049

· Quartz Control Plate -8° (-25°Z) : RE-72048

· Unjacketed Flow Tube (Glass) 50mm/4.5mL : RE-72051

· Unjacketed Flow Tube (Glass) 100mm/9mL : RE-72052

Purchase a quartz plate and a polarimeter as a set and receive a discount (for details, please contact the ATAGO sales department).
SAC-i 589/882
SAC-i 589/882

Automatic Polarimeter / Saccharimeter SAC-i 589/882

Close

    Automatic Polarimeter AP-300

    Our AP-300 has received	2003	“Itabashi Technology Gold Prize”

    The AP-300 fully automatic polarimeter measures a sample easily by setting the observation tube (filled with a liquid sample) in the sample chamber and pressing START.
    Digitally displayed measurement values are large and easy to read. The AP-300 generally used in pharmaceutical, perfume, cosmetic, industrial, chemical, and food factories is the best for measuring the angle of rotation. In addition, the built in International Sugar Scale is used widely in sugar factories.

    Specifications
    Model AP-300
    Cat.No. 5291
    Scale Angle of Rotation,
    International Sugar Scale (without temperature compensation),
    International Sugar Scale (with Automatic Temperature Compensation)
    Measurement Readings Angle of Rotation,
    International Sugar Scale (without temperature compensation),
    International Sugar Scale (with Automatic Temperature Compensation),
    Specific Optical Rotation, Concentration, and Purity
    Measurement Range Angle of Rotation : -89.999 to +89.999°
    International Sugar Scale : -130.000 to +130.000°Z
    Resolution Angle of Rotation : 0.001°
    International Sugar Scale : 0.001°Z
    Measurement Accuracy Angle of Rotation
    Displayed value : ±0.01° (-35.00 to +35.00°)
    Relative precision : ±0.2% (-35.01° to -89.99° , +35.01° to +89.99°)
    International Sugar Scale
    Displayed value : ±0.03°Z (-101.00 to +101.00°Z)
    Relative precision : ±0.2% (-130.00 to -101.01°Z , +101.01 to +130.00°Z)
    (Checked by reading a standard Quartz Plate)
    Temperature indication Resolution±0.1°, Accuracy:±0.5°
    Temperature correction range for International Sugar Scale 18.0 to 30.0°
    Display Panel Color LCD with backlight
    Light source white LED
    Measurement Wavelength 589nm (equivalent to the sodium-D line spectrum)
    Output Digital Printer DP-63 or DP-AD (Optional)
    • RS-232C
    Manual Calibration Enables manual calibration by measuring a standard Quartz Plate
    Power Supply AC100V to 240V 50/60Hz
    Included Accessories 100mm (5mL), 200mm (10mL)
    Observation tube (1each)
    Software, PolariSoft
    Dimensions & Weight 48.5×28.5×17.5cm, 14.4kg
    (Main Unit only)
    Power consumption 65VA
    Options

    · Special Packages Type A Temperature Controlled : Cat.No.5296

    · Special Packages Type B Temperature Compensation : Cat.No.5297

    · Digital Printer DP-63 (Thermal printer) : Cat.No.3118

    · Digital printer DP-AD (Dot matrix printer) : Cat.No.3123

    · Observation tube 50mm long OT-50 (A) 2.5mL : RE-72056

    · Observation tube 100mm OT-100(A) (SUS) 5mL : RE-72054

    · Observation tube 200mm long OT-200 (A) 10mL : RE-72055

    · Jacketed flow tube 100mm : RE-72034

    · Jacketed flow tube 200mm : RE-72035

    · Jacketed flow tube 50mm : RE-72036

    · Jacketed flow tube with funnel 100mm : RE-72033

    · Jacketed flow tube with funnel 200mm : RE-72032

    · Quartz control plate 34°(100°Z) : RE-72045

    · Quartz control plate 17°(50°Z) : RE-72044

    · Quartz control plate 8°(25°Z) : RE-72043

    · Quartz Control Plate -34° (-100°Z) : RE-72050

    · Quartz Control Plate -17° (-50°Z) : RE-72049

    · Quartz Control Plate -8° (-25°Z) : RE-72048

    · Unjacketed Flow Tube (Glass) 50mm/4.5mL : RE-72051

    · Unjacketed Flow Tube (Glass) 100mm/9mL : RE-72052

    * Calibration Certificate : Contact an ATAGO representative for details.

    Purchase a quartz plate and a polarimeter as a set and receive a discount (for details, please contact the ATAGO sales department).
    Parts

    · Deck glass : RE-6712

    · Rubber packing for observation tube : RE-6713

    · Ring nut for observation tube : RE-6714

    · Light source unit : RE-74806

    · Printer paper (regular) for Thermal printer : RE-8412

    · Printer paper (long-term storage) for Thermal printer : RE-8414

    · Printer paper for Dot matrix printer : RE-89403

    · Ribbon cassette : RE-89402

    AP-300
    AP-300

    Automatic Polarimeter AP-300

    Close
    Catalog Download 689KB

    Special Package (Recommended for sugar industry) AP-300 Type A Temperature Control

    ATAGO has prepared 2 different AP-300 packages for the sugar industry. Users have a choice between 2 types: Temperature Controlled Type A and Temperature Compensation Type B. The AP-300 comes with Automatic Temperature Compensation for International Sugar Scale. A Circulating Constant Temperature Bath is not necessary when the temperature compensation function is used or when the AP-300 is used in a temperature-controlled room.

    Specifications
    Model AP-300 Type A Temperature Control
    Cat.No. 5296
    Package Contents • AP-300
    • Jacketed flow tube with funnel
    (200mm - approximate volume 15mL)
    • Inner Lid (For Tube 200mm) : RE-76017
    * Circulating Constant Temperature Bath 60-C5 (Cat.No.1923) sold separately.
    AP-300
    AP-300

    Special Package (Recommended for sugar industry) AP-300 Type A Temperature Control

    Close
      Catalog Download 689KB

      Special Package (Recommended for sugar industry) AP-300 Type B No Temperature Control

      ATAGO has prepared 2 different AP-300 packages for the sugar industry. Users have a choice between 2 types: Temperature Controlled Type A and Temperature Compensation Type B. The AP-300 comes with Automatic Temperature Compensation for International Sugar Scale. A Circulating Constant Temperature Bath is not necessary when the temperature compensation function is used or when the AP-300 is used in a temperature-controlled room.

      Specifications
      Model AP-300 Type B No Temperature Control
      Cat.No. 5297
      Package Contents • AP-300
      • Unjacketed flow tube with funnel
      (200mm - approximate volume 15mL
      • Inner Lid (For Tube 200mm) : RE-76017
      AP-300
      AP-300

      Special Package (Recommended for sugar industry) AP-300 Type B No Temperature Control

      Close
        Catalog Download 689KB

        Special Package (Recommended for pharmaceutical industry) AP-300 Type C Temperature Control

        Both AP-300 packages include a GMP and GLP compliant Quartz Control Plate for calibration and a Digital Printer DP-AD (regular paper) for data recording. Choose between Package C, which includes a Constant Temperature Circulating Bath 60-C5, or Package D without temperature control.

        Specifications
        Model AP-300 Type C Temperature Control
        Cat.No. 5294
        Package Contents • AP-300
        • Jacketed flow tube (100mm)
        • Inner Lid (For Tube 100mm) : RE-76016
        • Quartz Control Plate (8°, 17°, or 34°)
        • Digital printer DP-AD
        • Printer paper for DP-AD
        • Ribbon cassette for DP-AD
        • Circulating Constant Temperature Bath 60-C5
        AP-300
        AP-300

        Special Package (Recommended for pharmaceutical industry) AP-300 Type C Temperature Control

        Close
          Catalog Download 689KB

          Special Package (Recommended for pharmaceutical industry) AP-300 Type D No Temperature Control

          Both AP-300 packages include a GMP and GLP compliant Quartz Control Plate for calibration and a Digital Printer DP-AD (regular paper) for data recording. Choose between Package C, which includes a Constant Temperature Circulating Bath 60-C4, or Package D without temperature control.

          Specifications
          Model AP-300 Type D No Temperature Control
          Cat.No. 5295
          Package Contents • AP-300
          • Quartz Control Plate (8°, 17°, or 34°)
          • Digital printer DP-AD
          • Printer paper for DP-AD
          • Ribbon cassette for DP-AD
          AP-300
          AP-300

          Special Package (Recommended for pharmaceutical industry) AP-300 Type D No Temperature Control

          Close
            Catalog Download 689KB

            Polarimeter POLAX-2L

            Polarimeter, which is known as an optical rotation meter, is an instrument to measure optical rotation of "optically active matter" such as saccharin, ascorbic acid and sodium glutamate.

            Specifications
            Model POLAX-2L
            Cat.No. 5223
            Scale Angle of rotation
            International sugar scale
            Measurement Range Angle of rotation : -179.95° to +180.00°
            International sugar scale : -130.0°Z to +130.0°Z
            Resolution Angle of rotation : 0.05°
            International sugar scale : 0.1°Z
            Measurement Accuracy Angle of rotation : ±0.10°
            International sugar scale : 0.3°Z
            Temperature compensation range 5 to 40°C
            Light source LED with interference filter
            Measurement Wavelength 589nm (equivalent to the sodium-D line spectrum)
            Power Supply AC100 to 240V 50/60Hz
            Included Accessories Observation tubes : 100mm tube and 200mm tube / each
            Dimensions & Weight 43×22×30cm, 10.3kg
            (Main Unit only)
            Options

            · Quartz control plate 34°(100°Z) : RE-72045

            · Quartz control plate 17°(50°Z) : RE-72044

            · Quartz control plate 8°(25°Z) : RE-72043

            · Quartz Control Plate -34° (-100°Z) : RE-72050

            · Quartz Control Plate -17° (-50°Z) : RE-72049

            · Quartz Control Plate -8° (-25°Z) : RE-72048

            · Unjacketed Flow Tube (Glass) 50mm/4.5mL : RE-72051

            · Unjacketed Flow Tube (Glass) 100mm/9mL : RE-72052

            * Calibration Certificate : Contact an ATAGO representative for details.

            Purchase a quartz plate and a polarimeter as a set and receive a discount (for details, please contact the ATAGO sales department).
            Parts

            · Observation tube 50mm long OT-50(P) 2.5mL : RE-6722

            · Observation tube 100mm long OT-100 (P) 5mL : RE-6720

            · Observation tube 200mm long OT-200 (P) 10mL : RE-6721

            · Small volume tube 100mm long (OT-100M) : RE-6708

            · Deck glass : RE-6712

            · Rubber packing for observation tube : RE-6713

            · Ring nut for observation tube : RE-6714

            · Rubber packing for small volume tube : RE-6715

            · Ring nut for small volume tube : RE-6717

            · Midget fuse (1A) : RE-5784

            POLAX-2L
            POLAX-2L

            Polarimeter POLAX-2L

            Close
              Catalog Download 590KB

              Circulating Constant Temperature Bath 60-C5

              The 60-C5 is an external circulation type constant temperature water tank provided with a thermo-module. The temperature can be set in the range of 10 to 60°C and the unit is perfectly suited for connection with a refractometer.

              An upgraded version of the 60-C4 model, featuring an increased tank capacity of 1.0L and an improved resolution of 0.1℃ which makes it even easier to use.

              Specifications
              Model 60-C5
              Cat.No. 1923
              Tank Capacity 1.0 lit
              Resolution 0.1℃
              Temperature Setting Range 10 to 60°C (water)
              Temperature control PID control method using a thermo-module
              Power Supply AC 100 to 240V, 50/60Hz
              Constant-Temperature Accuracy ±0.2°C
              Dimensions & Weight 20.4×33.6×28.9cm, 9.0kg
              (Main Unit only)
              Power consumption 250VA
              Flow Rate 6 lit / min
              60-C5
              60-C5

              Circulating Constant Temperature Bath 60-C5

              Close