Multi-wavelength Abbe Refractometers

ATAGO's Multi-Wavelength Abbe Refractometers have the ability to measure liquids or solids at different wavelengths using interchangeable filters. Measurements are displayed digitally for easy reading.

Multi-Wavelength Abbe Refractometer DR-M2

Refractive index or Abbe number (νd or νe) can be measured at different wavelengths ranging from 450 to 1,100nm.
The DR-M2 digitally displays measurement result of refractive index or Abbe number on the LCD.
Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs.
This refractometer is connectable with Digital printer DP-63(B) (Optional).

Specifications
Model DR-M2
Cat.No. 1410
Scale Refractive index
Abbe number
Measurement Range Refractive index 1.3278 to 1.7379 (Wavelength 450nm)
Refractive index 1.3000 to 1.7100 (Wavelength 589nm)
Refractive index 1.2912 to 1.7011 (Wavelength 680nm)
Refractive index 1.2743 to 1.6840 (Wavelength 1,100nm)
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index : ±0.0002
(With the attached test piece at 500 to 650nm)
Ambient Temperature 5 to 40゚C
Measurement Temperature Range 5 to 50゚C
(With circulating constant water bath)
Display Panel LCD
Light source Halogen lamp
Output For printer, DP-63 (B) (Optional)
Wavelength Range From 450 to 1100nm (with interference filters)
(For measurement at wavelengths ranging from 681 to 1100nm, the Near Infrared Ray Viewer (Optional is required)
Power Supply AC100 to 240V, 50/60Hz
Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
15×33×11cm, 3.2kg (Light source unit)
Power consumption 160VA
Special Order Option : The sample stage height can be customized.
Options

· Lighting glass for film measuerment : RE-6191

· Digital printer DP-63(B) (Thermal printer) : Cat.No.3135

· Interference filter 589(D)nm : RE-3520

· Interference filter 486(F)nm : RE-3521

· Interference filter 656(C)nm : RE-3522

· Interference filter 546(e)nm : RE-3523

· Interference filter 480(F`)nm : RE-3524

· Interference filter 644(C`)nm : RE-3525

· Interference filter (select one wavelength) : RE-3526

· Interference filter 450 to 539nm : RE-3526-1

· Interference filter 540 to 680nm : RE-3526-2

· Interference filter 681 to 799nm : RE-3526-3

· : Interference filter 800 to 1100nm : RE-3526-4

· Near-infrared ray viewer : RE-9119

· Eyepiece for polarizing : RE-1146

* Calibration Certificate : Contact an ATAGO representative for details.

Parts

· Test piece A with m-naphthalene : RE-1195

· Main & secondary prism : RE-1600

· Main & secondary prism : RE-16500

· Illuminating lamp : RE-4170

· Pack of desiccant tablets : RE-1592

*Please inform us of a serial number in the case of an order.

DR-M2
DR-M2

Multi-Wavelength Abbe Refractometer DR-M2

Close
Catalog Download 2.01MB

Multi-Wavelength Abbe Refractometer DR-M4

Refractive index or Abbe number (νd or νe) can be measured at different wavelengths ranging from 450 to 1,100nm (For measurement at wavelengths ranging from 681 to 1,100nm, the Optional Near Infrared Ray Viewer (RE-9119) is required.
The DR-M4 displays measurement result of refractive index or Abbe number digitally on the LCD.
Measurement can be achieved by matching the boundary line with the intersection point of the cross hairs.
This refractometer is connectable with Digital printer DP-63 (B)(Optional) .

Specifications
Model DR-M4
Cat.No. 1414
Scale Refractive index
Abbe number
Measurement Range Refractive index : 1.5219 to 1.9220 (at 450nm)
Refractive index : 1.4700 to 1.8700 (at 589nm)
Refractive index : 1.4545 to 1.8544 (at 680nm)
Refractive index : 1.4260 to 1.8259 (at 1,100nm)
Minimum Indication Refractive index : 0.0001
Abbe number : 0.1
Measurement Accuracy Refractive index : ±0.0002
(With the attached test piece at 500 to 650nm)
Ambient Temperature 5 to 40゚C
Measurement Temperature Range 5 to 50゚C
Display Panel LCD
Light source Halogen lamp, 12V 50W
Output For printer, DP-63 (B) (Optional)
Wavelength Range From 450 to 1100nm (with interference filters)
(For measurement at wavelengths ranging from 681 to 1100nm, the Near Infrared Ray Viewer (Optional is required)
Power Supply AC100 to 240V, 50/60Hz
Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
15×33×11cm, 3.2kg (Light source unit)
Power consumption 160VA
Special Order Option : The sample stage height can be customized.
Options

· Lighting glass for film measuerment : RE-6193

· Digital printer DP-63(B) (Thermal printer) : Cat.No.3135

· Interference filter 589(D)nm : RE-3520

· Interference filter 486(F)nm : RE-3521

· Interference filter 656(C)nm : RE-3522

· Interference filter 546(e)nm : RE-3523

· Interference filter 480(F`)nm : RE-3524

· Interference filter 644(C`)nm : RE-3525

· Interference filter (select one wavelength) : RE-3526

· Interference filter 450 to 539nm : RE-3526-1

· Interference filter 540 to 680nm : RE-3526-2

· Interference filter 681 to 799nm : RE-3526-3

· : Interference filter 800 to 1100nm : RE-3526-4

· Near-infrared ray viewer : RE-9119

· Eyepiece for polarizing : RE-1146

* Calibration Certificate : Contact an ATAGO representative for details.

Parts

· Test piece C with m-naphthalene : RE-1197

· Main & secondary prism : RE-1640

· Illuminating lamp : RE-4170

· Pack of desiccant tablets : RE-1592

*Please inform us of a serial number in the case of an order.

DR-M4
DR-M4

Multi-Wavelength Abbe Refractometer DR-M4

Close
    Catalog Download 2.01MB

    Multi-Wavelength Abbe Refractometer DR-M2/1550

    Refractive index or Abbe number (νd or νe) can be measured at different wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-63 (B) (Optional).

    Specifications
    Model DR-M2/1550
    Cat.No. 1412
    Scale Refractive index
    Abbe number
    Measurement Range Refractive index : 1.3278 to 1.7379 (at 450nm)
    Refractive index : 1.3000 to 1.7100 (at 589nm)
    Refractive index : 1.2912 to 1.7011 (at 680nm)
    Refractive index : 1.2743 to 1.6840 (at 1,100nm)
    Refractive index : 1.2662 to 1.6759 (at 1,550nm)
    Minimum Indication Refractive index : 0.0001
    Abbe number : 0.1
    Measurement Accuracy Refractive index : ±0.0002
    (With the attached test piece at 589nm)
    Ambient Temperature 5 to 40゚C
    Measurement Temperature Range 5 to 50°C
    (Temperature range available of the circulating water)
    Display Panel LCD
    Light source Monochromatic light source device
    Dimensions & Weight : 22×30×20 to 30cm, 5.2kg
    Power consumption : 240VA
    Output For printer, DP-63 (B)(Optional)
    Wavelength Range From 450 to 1,550nm
    (With interference filters)
    Main Components Refractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter (589nm).
    Power Supply AC100 to 240V, 50/60Hz
    Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
    15×33×11cm, 3.2kg (Power supply unit)
    Power consumption 160VA (Refractometer, Power supply unit)
    Special Order Option : The sample stage height can be customized.
    Options

    · Lighting glass for film measuerment : RE-6191

    · Digital printer DP-63(B) (Thermal printer) : Cat.No.3135

    · Interference filter 589(D)nm : RE-16501

    · Interference filter 486(F)nm : RE-16502

    · Interference filter 656(C)nm : RE-16503

    · Interference filter 546(e)nm : RE-16504

    · Interference filter 480(F`)nm : RE-16505

    · Interference filter 644(C`)nm : RE-16506

    · Interference filter (select one wavelength) : RE-16507

    · Interference filter 450 to 539nm : RE-16507-1

    · Interference filter 540 to 680nm : RE-16507-2

    · Interference filter 681 to 799nm : RE-16507-3

    · Interference filter 800 to 1550nm : RE-16507-4

    · Near-infrared ray viewer : RE-9119

    · Eyepiece for polarizing : RE-1146

    * Calibration Certificate : Contact an ATAGO representative for details.

    Parts

    · Test piece A with m-naphthalene : RE-1195

    · Main & secondary prism : RE-16500

    · Pack of desiccant tablets : RE-1592

    *Please inform us of a serial number in the case of an order.

    DR-M2/1550
    DR-M2/1550

    Multi-Wavelength Abbe Refractometer DR-M2/1550

    Close
      Catalog Download 2.01MB

      Multi-Wavelength Abbe Refractometer DR-M4/1550

      Refractive index or Abbe number (νd or νe) can be measured atdifferent wavelengths ranging from 450 to 1,550nm. This refractometer digitallys display measurement result of refractive index or Abbe number on the LCD. This measurement can be achieved by matching the boundary line withthe intersection point of the cross hairs This is connectable with Digital printer DP-63(B) (Optional).

      Specifications
      Model DR-M4/1550
      Cat.No. 1415
      Scale Refractive index
      Abbe number
      Measurement Range Refractive index : 1.5219 to 1.9155 (at 450nm)
      Refractive index : 1.4700 to 1.8700 (at 589nm)
      Refractive index : 1.4561 to 1.8544 (at 680nm)
      Refractive index : 1.4310 to 1.8259 (at 1,100nm)
      Refractive index : 1.4215 to 1.8136 (at 1,550nm)
      Minimum Indication Refractive index : 0.0001
      Abbe number : 0.1
      Measurement Accuracy Refractive index : ±0.0002
      (With the attached test piece at 589nm)
      Ambient Temperature 5 to 40゚C
      Measurement Temperature Range 5 to 50゚C
      Display Panel LCD
      Light source Monochromatic light source device
      Dimensions & Weight : 22×30×20 to 30cm, 5.2kg
      Power Consumption : 240VA
      Output For printer, DP-63 (B) (Optional)
      Wavelength Range From 450 to 1,550nm
      (With interference filters)
      Main Components Refractometer, Power supply unit, Monochromatic light source device, Near infrared ray viewer, Interference filter (589nm) .
      Power Supply AC100 to 240V 50/60Hz
      Dimensions & Weight 13×29×31cm, 6.0kg (Refractometer)
      15×33×11cm, 3.2kg (Power supply unit)
      Power consumption 160VA(Refractometer, Power supply unit)
      Special Order Option : The sample stage height can be customized.
      Options

      · Lighting glass for film measuerment : RE-6193

      · Digital printer DP-63(B) (Thermal printer) : Cat.No.3135

      · Interference filter 589(D)nm : RE-16501

      · Interference filter 486(F)nm : RE-16502

      · Interference filter 656(C)nm : RE-16503

      · Interference filter 546(e)nm : RE-16504

      · Interference filter 480(F`)nm : RE-16505

      · Interference filter 644(C`)nm : RE-16506

      · Interference filter (select one wavelength) : RE-16507

      · Interference filter 450 to 539nm : RE-16507-1

      · Interference filter 540 to 680nm : RE-16507-2

      · Interference filter 681 to 799nm : RE-16507-3

      · Interference filter 800 to 1550nm : RE-16507-4

      · Near-infrared ray viewer : RE-9119

      · Eyepiece for polarizing : RE-1146

      * Calibration Certificate : Contact an ATAGO representative for details.

      Parts

      · Test piece C with m-naphthalene : RE-1197

      · Main & secondary prism : RE-1640

      · Pack of desiccant tablets : RE-1592

      *Please inform us of a serial number in the case of an order.

      DR-M4/1550
      DR-M4/1550

      Multi-Wavelength Abbe Refractometer DR-M4/1550

      Close
        Catalog Download 2.01MB

        Circulating Constant Temperature Bath 60-C5

        The 60-C5 is an external circulation type constant temperature water tank provided with a thermo-module. The temperature can be set in the range of 10 to 60°C and the unit is perfectly suited for connection with a refractometer.

        An upgraded version of the 60-C4 model, featuring an increased tank capacity of 1.0L and an improved resolution of 0.1℃ which makes it even easier to use.

        Specifications
        Model 60-C5
        Cat.No. 1923
        Tank Capacity 1.0 lit
        Resolution 0.1℃
        Temperature Setting Range 10 to 60°C (water)
        Temperature control PID control method using a thermo-module
        Power Supply AC 100 to 240V, 50/60Hz
        Constant-Temperature Accuracy ±0.2°C
        Dimensions & Weight 20.4×33.6×28.9cm, 9.0kg
        (Main Unit only)
        Power consumption 250VA
        Flow Rate 6 lit / min
        60-C5
        60-C5

        Circulating Constant Temperature Bath 60-C5

        Close