In-line Brix-Monitor

These in-line models can be incorporated in piping of manufacturing plants, liquid mixing devices, and washing apparatuses to continuously measure the concentration of various liquids.
They are suitable for use in the control of mixing, concentration, fermentation, and control of the concentration of water-based or alkali-based detergent, etc.

In-line Brix-Monitor CM-800α

This new addition to the CM series is compatible with the PRM-100α fittings.
Fittings are available in a wide variety of shapes and sizes.
The accuracy is ±0.1% across the entire range of 0-80% Brix.

Specifications
Model CM-800α
Cat.No. 3564
Scale Brix [*1]
(Automatic Temperature Compensation according to the sample liquid)
Temperature
Measurement Range Brix : 0.0 to 80.0%
Temperature : -15 to 160゚C / 5 to 320゚F
Resolution Brix : 0.01 or 0.1%
(with an option to display measurements between 0.00 and 9.99% to the 2nd decimal place)
Temperature : 1゚C / 1゚F
Measurement Accuracy Brix : ±0.1%
Temperature : ±1゚C / ±1゚F
Temperature compensation range 5 to 100゚C (Automatic Temperature Compensation)
Wetted parts temperature resistance -30 to 150゚C
Ambient Temperature 5 to 40゚C
Indication Brix : -2.0 to 80.0%
Temperature : -15 to 160゚C / 5 to 320゚F
Light source LED(D-line approximation)
Temperature sensor Thin film platinum sensor
Materials in contact with the solution Prism : Sapphire
Prism stage : SUS316L
Prism pressure resistance 0.98MPa(10kgf/cm2)
Output (1) Recorder output : DC 4 to 20mA
Any value between Brix 1% through 80% can be set.
(2) RS-232C output
Power Supply DC24V
International Protection Class IP67 Dust-tight and Protected against splashing water.
Included Accessories Power input cable (1m) [*2]
Dimensions & Weight CM-800α(Main Unit only)
160(W)×167(D)×110(H) mm、 2.4kg
AC Adapter(AD-32、AD-33、AD-34)
160(W)× 60(D)×110(H) mm、 1.1kg
Power consumption 3VA
[*1] : Contact ATAGO if you are interested in using the CM-800α to measure other types of solution.
[*2] : The cable can be ordered to a custom length of up to 5m.
Options

See here for other accessories.

See here for fitting options.

* Calibration Certificate : Contact an ATAGO representative for details.

CM-800α
CM-800α

In-line Brix-Monitor CM-800α

Close
    SUS316L customizable PROFIBUS compatible VARIVENT compatible
    Catalog Download 527KB

    In-line Ethylene Glycol Monitor CM-800α-EG

    The CM-800α-EG is specially designed for in-line concentration measurements of ethylene glycol solutions used as coolants, brine, anti-freeze, and de-icing fluids. It also has a secondary scale for the freezing point.

    Specifications
    Model CM-800α-EG
    Cat.No. 3531
    Scale E.G.
    (Automatic Temperature Compensation according to the sample liquid)
    Freezing point
    Temperature
    Measurement Range E.G. : 0.0 to 90.0%
    Freezing point : -50 to 0゚C / -58 to 32゚F
    Temperature : -15 to 160゚C / 5 to 320゚F
    Resolution E.G. : 0.1%
    Freezing point : 1゚C / 1゚F
    Temperature : 1゚C / 1゚F
    Measurement Accuracy E.G. : ±0.4%
    Freezing point : ±1゚C / ±1゚F
    Temperature : ±1゚C / ±1゚F
    Temperature compensation range 5 to 100゚C
    (Automatic Temperature Compensation)
    Wetted parts temperature resistance -30 to 150゚C
    Ambient Temperature 5 to 40゚C
    Indication E.G. : -2.0 to 105.5%
    Freezing point : -50 to 0゚C / -58 to 32゚F
    Temperature : 0 to 130゚C / 32 to 266゚F
    Light source LED
    Temperature sensor Thin film platinum sensor
    Materials in contact with the solution Prism : Sapphire
    Prism stage : SUS316L
    Prism pressure resistance 0.98MPa(10kgf/cm2)
    Output (1) Recorder output : DC 4 to 20mA
    (2) RS-232C output
    Power Supply DC24V
    International Protection Class IP67
    Dust-tight and Protected against splashing water.
    Included Accessories Power input cable (1m) [*1]
    Dimensions & Weight CM-800α(Main Unit only)
    160(W)×167(D)×110(H) mm、 2.4kg
    AC Adapter(AD-32、AD-33、AD-34)
    160(W)× 60(D)×110(H) mm、 1.1kg
    Power consumption 3VA
    [*1] : The cable can be ordered to a custom length of up to 5m.
    Options

    · Stand (Stand for mounting the CM-800α and the AC adapter) : RE-8607

    · AC adapter AD-32 (AC100V) : Cat.No.3527

    · AC adapter AD-33 (AC110 to 120V) : Cat.No.3528

    · AC adapter AD-34 (AC220 to 240V) : Cat.No.3529

    See here for fitting options.

    * Calibration Certificate : Contact an ATAGO representative for details.

    CM-800α-EG
    CM-800α-EG

    In-line Ethylene Glycol Monitor CM-800α-EG

    Close
      PROFIBUS compatible VARIVENT compatible

      In-line Propylene Glycol Monitor CM-800α-PG

      The CM-800α-PG is specially designed for in-line concentration measurements of propylene glycol solutions used as coolants, brine, anti-freeze, and de-icing fluids. It also has a secondary scale for the freezing point.

      Specifications
      Model CM-800α-PG
      Cat.No. 3532
      Scale P.G.
      (Automatic Temperature Compensation according to the sample liquid)
      Freezing point
      Temperature
      Measurement Range P.G. : 0.0 to 90.0%
      Freezing point : -50 to 0゚C / -58 to 32゚F
      Temperature : -15 to 160゚C / 5 to 320゚F
      Resolution P.G. : 0.1%
      Freezing point : 1゚C / 1゚F
      Temperature : 1゚C / 1゚F
      Measurement Accuracy P.G. : ±0.4%
      Freezing point : ±1゚C / ±1゚F
      Temperature : ±1゚C / ±1゚F
      Temperature compensation range 5 to 100゚C
      (Automatic Temperature Compensation)
      Wetted parts temperature resistance -30 to 150゚C
      Ambient Temperature 5 to 40゚C
      Indication P.G. : -2.0 to 105.5%
      Freezing point :-50 to 0゚C / -58 to 32゚F
      Temperature : 0 to 130゚C / 32 to 266゚F
      Light source LED (D-line approximation)
      Temperature sensor Thin film platinum sensor
      Materials in contact with the solution Prism : Sapphire
      Prism stage : SUS316L
      Prism pressure resistance 0.98MPa(10kgf/cm2)
      Output RS-232C, DC 4 to 20mA
      Materials Prism : Sapphire
      Prism stage : SUS316L
      Power Supply DC24V
      International Protection Class IP67
      Dust-tight and Protected against splashing water.
      Included Accessories Power input cable (1m) [*1]
      Dimensions & Weight CM-800α(Main Unit only)
      160(W)×167(D)×110(H) mm、 2.4kg
      AC Adapter(AD-32、AD-33、AD-34)
      160(W)× 60(D)×110(H) mm、 1.1kg
      Power consumption 3VA
      [*1] : The cable can be ordered to a custom length of up to 5m.
      Options

      · Stand (Stand for mounting the CM-800α and the AC adapter) : RE-8607

      · AC adapter AD-32 (AC100V) : Cat.No.3527

      · AC adapter AD-33 (AC110 to 120V) : Cat.No.3528

      · AC adapter AD-34 (AC220 to 240V) : Cat.No.3529

      * Calibration Certificate : Contact an ATAGO representative for details.

      See here for fitting options.

      CM-800α-PG
      CM-800α-PG

      In-line Propylene Glycol Monitor CM-800α-PG

      Close
        PROFIBUS compatible VARIVENT compatible

        In-line Salinity Monitor CM-800α-SW

        This is an in-line refractometer for concentrations of sodium chloride in water (0.0-28.0%).
        It is built to the same specifications as the original CM-800α with the Brix scale.

        Specifications
        Model CM-800α-SW
        Cat.No. 3533
        Scale Salinity (Automatic Temperature Compensation according to the sample liquid)
        Temperature
        Measurement Range Salinity : 0.0 to 28.0%
        Temperature : -15 to 160゚C / 5 to 320゚F
        Resolution Salinity : 0.01 or 0.1%
        (with an option to display measurements between 0.00 and 9.99% to the 2nd decimal place)
        Temperature : 1゚C / 1゚F
        Measurement Accuracy Salinity : ±0.1%
        Temperature : ±1゚C / ±2゚F
        Temperature compensation range 5 to 100゚C (Automatic Temperature Compensation)
        Wetted parts temperature resistance -30 to 150゚C
        Ambient Temperature 5 to 40゚C
        Indication Salinity : -2.0 to 28.5%
        Temperature : -7 to 130゚C / 19 to 266゚F
        Light source LED (D-line approximation)
        Temperature sensor Thin film platinum sensor
        Materials in contact with the solution Prism : Sapphire
        Prism stage : SUS316L
        Prism pressure resistance 0.98MPa(10kgf/cm2)
        Output (1) Recorder output : DC 4 to 20mA
        (2) RS-232C output
        Power Supply DC24V
        International Protection Class IP67 Dust-tight and Protected against splashing water.
        Included Accessories Power input cable (1m) [*1]
        Dimensions & Weight CM-800α(Main Unit only)
        160(W)×167(D)×110(H) mm、 2.4kg
        AC Adapter(AD-32、AD-33、AD-34)
        160(W)× 60(D)×110(H) mm、 1.1kg
        Power consumption 3VA
        [*1] : The cable can be ordered to a custom length of up to 5m.
        Options

        · Stand (Stand for mounting the CM-800α and the AC adapter) : RE-8607

        · AC adapter AD-32 (AC100V) : Cat.No.3527

        · AC adapter AD-33 (AC110 to 120V) : Cat.No.3528

        · AC adapter AD-34 (AC220 to 240V) : Cat.No.3529

        * Calibration Certificate : Contact an ATAGO representative for details.

        See here for fitting options.

        CM-800α-SW
        CM-800α-SW

        In-line Salinity Monitor CM-800α-SW

        Close
          PROFIBUS compatible VARIVENT compatible

          In-line Brix-Monitor CM-BASEα(A)

          Easy operation with only one cable for power supply and data output.Optimized for automation of real-time concentration monitoring.
          The CM-BASEα (A) transmits data via 4-20mA signals.

          Specifications
          Model CM-BASEα(A)
          Cat.No. 3603
          Scale Brix
          Measurement Range Brix : 0.0 to 33.0%
          Resolution Brix : 0.1%
          Measurement Accuracy Brix ±0.5%
          Temperature ±2.0゚C
          Temperature compensation range 10 to 50゚C
          (Automatic Temperature Compensation)
          Ambient Temperature 10 to 40゚C
          Indication Brix : -2.0 to 33.5%
          Light source LED (D-line approximation)
          Temperature sensor Thin film platinum sensor
          Materials in contact with the solution Prism : Sapphire
          Prism stage : SUS316L
          Prism pressure resistance 0.98MPa (10kgf/cm2)
          Output Recorder output : DC 4 to 20mA
          Power Supply DC24V(Allowable fluctuation is ±10%)
          International Protection Class IP64
          Dust-tight and Protected against splashing water.
          Included Accessories Signal cable
          (DC24V input, Recorder output)
          2m [*1]
          Dimensions & Weight 90×90×59mm, 820g (Main unit only)
          Power consumption 0.6VA
          [*1] : The cable can be ordered to a custom length of up to 100m.
          CM-BASEα(A)
          CM-BASEα(A)

          In-line Brix-Monitor CM-BASEα(A)

          Close
          SUS316L customizable PROFIBUS compatible VARIVENT compatible

          In-line Brix-Monitor CM-BASEα(D)

          Easy operation with only one cable for power supply and data output.Optimized for automation of real-time concentration monitoring.
          The CM-BASEα(D) transmits data to a computer via RS-232C.

          Specifications
          Model CM-BASEα(D)
          Cat.No. 3604
          Scale Brix
          Measurement Range Brix : 0.0 to 33.0%
          Resolution Brix : 0.1%
          Measurement Accuracy Brix ±0.5%
          Temperature ±2.0゚C
          Temperature compensation range 10 to 50°C
          ( Automatic Temperature Compensation)
          Ambient Temperature 10 to 40°C
          Indication Brix : -2.0 to 33.5%
          Light source LED (D-line approximation)
          Temperature sensor Thin film platinum sensor
          Materials in contact with the solution Prism:Sapphire
          Prism stage:SUS316L
          Prism pressure resistance 0.98MPa(10kgf/cm2)
          Output RS-232C
          Communications parameters Baud rate : 2400bps
          Partity : Even
          Data length : 7bit
          Stop bit : 1bit
          Transmit data aa.a, bb.b(Brix, Temperature)
          (Example) Brix =19.5%,Temperature = 20.3°C ⇒ "19.5,20.3"
          International Protection Class IP64
          Dust-tight and Protected against splashing water.
          Included Accessories Signal cable
          (DC24V input, RS-232C output)
          2m [*1]
          Dimensions & Weight 90×90×59mm, 820g (Main unit only)
          Power consumption 0.6VA
          [*1] : The cable can be ordered to a custom length of up to 15m.
          CM-BASEα(D)
          CM-BASEα(D)

          In-line Brix-Monitor CM-BASEα(D)

          Close
          SUS316L customizable PROFIBUS compatible VARIVENT compatible

          IN-LINE BRIX‐MONITOR CM-BASEβ (A)

          In order to meet the need of our users, the CM-BASEβ has designed to attach to the edge of a tank or pot.
          This model is recommended for various applications for the industrial field, such as cutting oil.

          Specifications
          Model CM-BASEβ (A)
          Cat.No. 3616
          Scale Brix
          Measurement Range Brix : 0.0 to 33.0%
          Minimum Indication Brix : 0.1%
          Measurement Accuracy Brix ±0.5%
          (for measurement value of Brix 0.0 to 33.0%)
          Measurement Temperature 5 to 40℃
          Temperature compensation range 10 to 50℃
          Light source LED (D-line approximation)
          Materials in contact with the solution Prism: Sapphire
          Prism stage : aluminium
          Cable analog output cable:standard length: 2m(Can be extended up to maximum of 15m.)
          Power Supply DC24V (Allowable fluctuation is ±10%)
          Constant-Temperature Accuracy ±2.0℃
          International Protection Class IP64 (Immersed part IP67)
          Dimensions & Weight 90(W)×90(D)×57.7+200mm(H)
          873g
          Output terminals Brix -2.0 to 33.5% = DC4 to 20mA
          CM-BASEβ (A)
          CM-BASEβ (A)

          IN-LINE BRIX‐MONITOR CM-BASEβ (A)

          Close

            IN-LINE BRIX‐MONITOR CM-BASEβ (D)

            In order to meet the need of our users, the CM-BASEβ has designed to attach to the edge of a tank or pot.
            This model is recommended for various applications for the industrial field, such as cutting oil.

            Specifications
            Model CM-BASEβ (D)
            Cat.No. 3626
            Scale Brix
            Measurement Range Brix : 0.0 to 33.0%
            Minimum Indication Brix : 0.1%
            Measurement Accuracy Brix ±0.5%
            (for measurement value of Brix 0.0 to 33.0%)
            Measurement Temperature 5 to 40℃
            Temperature compensation range 10 to 50℃
            Light source LED (D-line approximation)
            Materials in contact with the solution Prism: Sapphire
            Prism stage : aluminium
            Cable analog output cable:standard length: 2m(Can be extended up to maximum of 15m.)
            Power Supply DC24V (Allowable fluctuation is ±10%)
            Constant-Temperature Accuracy ±2.0℃
            International Protection Class IP64 (Immersed part IP67)
            Dimensions & Weight 90(W)×90(D)×57.7+200mm(H)
            873g
            Output terminals RS-232C output: Brix and temperature
            CM-BASEβ (D)
            CM-BASEβ (D)

            IN-LINE BRIX‐MONITOR CM-BASEβ (D)

            Close