ATAGO's Polarimeters measure the optical rotation of optically active substances such as saccharide, ascorbic acid, sodium glutamate and others.

Automatic Polarimeter AP-300

Our AP-300 has received
 2003  “Itabashi Technology Gold Prize”

The AP-300 fully automatic polarimeter measures a sample easily by setting the observation tube ( filled with a liquid sample ) in the sample chamber and pressing START.
Digitally displayed measurement values are large and easy to read. The AP-300 generally used in pharmaceutical, perfume, cosmetic, industrial, chemical, and food factories is the best for measuring the angle of rotation. In addition, the built in International Sugar Scale is used widely in sugar factories.


Enlargement
Quantity
>about the icons Automatic Temperature Compensation Can be connected to a printer RS-232C Interface Digital display AC outlet (AC100 to 240V)
Model AP-300 Cat.No. 5291
Measurement Scales Angle of Rotation,
International Sugar Scale (without temperature compensation),
International Sugar Scale (with Automatic Temperature Compensation)
Measurement Readings Angle of Rotation,
International Sugar Scale (without temperature compensation),
International Sugar Scale (with Automatic Temperature Compensation ),
Specific Optical Rotation, Concentration, and Purity
Measurement Range Angle of Rotation
-89.99 to +89.99°
International Sugar Scale
-130.00 to +130.00°Z
Minimum Indication Angle of Rotation 0.01°
International Sugar Scale
0.01°Z
Measurement Accuracy Angle of Rotation
   Displayed value    ±0.01° (- 35.00 to + 35.00° )
   Relative precision ±0.2% (- 35.01° to - 89.99° , + 35.01° to + 89.99° )
International Sugar Scale
   Displayed value    ±0.03°Z (- 101.00 to + 101.00° )
   Relative precision ±0.2% (- 130.00 to - 101.01°Z , + 101.01 to + 130.00°Z )
( Checked by reading a standard Quartz Plate )
Temperature correction range for International Sugar Scale 18.0 to 30.0° C Manual Calibration Enables manual calibration by measuring a standard Quartz Plate
Measurement Wavelength 589nm(D-line) Display Panel Color LCD with backlight
Power Supply AC100V to 240V 50/60Hz
Power Consumption 50VA Output Terminals Digital Printer DP-63 or
DP-AD  ( Optional )
• RS-232C
Dimensions & Weight 48.5×28.5×17.5cm, 13.9kg
(Main Unit only)
Accessories 100mm (5ml), 200mm (10ml)
Observation tube (1each)
Optional Special Packages Type A Temperature Controlled : Cat.No.5296
Special Packages Type B Temperature Compensation : Cat.No.5297
Digital Printer DP-63 : Cat.No.3118
Digital printer DP-AD : Cat.No.3123
• Observation tube 100mm long OT-100 (A) : RE-72001
• Observation tube 200mm long OT-200 (A) : RE-72002
• Jacketed flow tube 100mm : RE-72034
• Jacketed flow tube 200mm : RE-72035
• Jacketed flow tube 50mm : RE-72036
• Jacketed flow tube with funnel 100mm : RE-72033
• Jacketed flow tube with funnel 200mm : RE-72032
Quartz control plate 34° : RE-72045
Quartz control plate 17° : RE-72044
Quartz control plate 8° : RE-72043
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Deck glass : RE-6712
• Rubber packing for observation tube : RE-6713
• Ring nut for observation tube : RE-6714
• Light source unit : RE-74806
Printer paper (regular) for DP-63 : RE-8412
Printer paper (long-term storage) for DP-63 : RE-8414
Printer paper for DP-AD : RE-89403
Ribbon cassette for DP-AD : RE-89402
  Catalog Download
Go to the product search GO TOP

Special Package ( Recommended for sugar industry )

ATAGO has prepared 2 different AP-300 packages for the sugar industry. Users have a choice between 2 types: Temperature Controlled Type A and Temperature Compensation Type B. The AP-300 comes with Automatic Temperature Compensation for International Sugar Scale. A Circulating Constant Temperature Bath is not necessary when the temperature compensation function is used or when the AP-300 is used in a temperature-controlled room.


Enlargement
>about the icons Automatic Temperature Compensation Can be connected to a printer RS-232C Interface Digital display AC outlet (AC100 to 240V)
Model Type A
Temperature Controlled
Type B
Temperature Compensation
Cat.No.
5296 5297
Package Contents

• AP-300 (including accessories)
• Jacketed flow tube with funnel and temperature sensor for jacket
(200mm - approximate volume 15ml)
* Circulating Constant Temperature Bath 60-C3 (Cat.No.1921) sold separately.

• AP-300 (including accessories)
• Unjacketed flow tube with funnel
(200mm - approximate volume 15ml)

Confirm Quotation
Request
Quantity
Quantity
  Catalog Download
Go to the product search GO TOP

Special Package ( Recommended for pharmaceutical industry )

Both AP-300 packages include a GMP and GLP compliant Quartz Control Plate for calibration and a Digital Printer DP-AD (regular paper) for data recording. Choose between Package C, which includes a Constant Temperature Circulating Bath 60- C3, or Package D without temperature control.


Enlargement
>about the icons Automatic Temperature Compensation Can be connected to a printer RS-232C Interface Digital display AC outlet (AC100 to 240V)
Model Type C
Temperature Controlled
Type D
Without Temperature Contorolled
Cat.No.
5294 5295
Package Contents

• AP-300 (including accessories)
• Jacketed flow tube (100mm)
• Inner Lid (For Tube 100mm)
• Quartz Control Plate (8°, 17°, or 34°)
• Digital printer DP-AD
• Printer paper for DP-AD
• Ribbon cassette for DP-AD
• Circulating Constant Temperature Bath 60-C3

• AP-300 (including accessories)
• Jacketed flow tube (100mm)
• Quartz Control Plate (8°, 17°, or 34°)
• Digital printer DP-AD
• Printer paper for DP-AD
• Ribbon cassette for DP-AD

Confirm Quotation
Request
Quantity
Quantity
  Go to the product search GO TOP

Digital Printer DP-63

The DP-63 is a printer for Automatic Polarimeter AP-300, AP-100. It automatically prints out Angle of rotation, International sugar scale, Specific optical rotation, Concentration, Purity, Length of observation tube, Measurement temperature, Sample number Date, Month, Year and Time.


Enlargement
Quantity
Model DP-63 Cat.No. 3118
Printing Method Thermal dot printing Power Supply AC adapter (Input voltage : AC100 to 240V)
Power Consumption 13VA Dimensions & Weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-63 : RE-8412
Printer paper (long-term storage)for DP-63 : RE-8414
Go to the product search
GO TOP

Digital printer DP-AD

The DP-AD is a printer for Automatic Polarimeter AP-300, AP-100. It automatically prints out Angle of rotation, International sugar scale, Specific optical rotation, Concentration, Purity, Length of observation tube, Measurement temperature, Sample number Date, Month, Year and Time.The DP-AD uses regular rolled plain paper (not thermal).


Enlargement
Quantity
Model DP-AD Cat.No. 3123
Printing method Impact dot printing Power Supply From AC adapter ( Input voltage:AC100 to 240V )
Power consumption 7VA Dimensions & weight 11×18×9cm, 470g
(Main Uint only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper for DP-AD : RE-89403
Ribbon cassette for DP-AD : RE-89402
go to product search
GO TOP

Polarimeter POLAX-2L

Polarimeter, which is known as an optical rotation meter, is an instrument to measure optical rotation of "optically active matter" such as saccharin, ascorbic acid and sodium glutamate.


Enlargement
Quantity
>about the icons Digital display AC outlet (AC100 to 240V)
Model POLAX-2L Cat.No. 5223
Measurement Range Angle of rotation :
-179.95° to +180.00°
International sugar scale
-130.0°Z to +130.0°Z
Minimum Indication Angle of rotation 0.05°
International sugar scale
0.1°Z
Measurement Accuracy Angle of rotation ±0.10°
International sugar scale
±0.3°Z
Measurement temperature range 5 to 40° C
Light Source LED with interference filter
( 589nm )
Accessories Observation tubes : 100mm tube and 200mm tube / each
Power Supply AC100 to 240V 50/60Hz Dimensions & Weight 43×21×29cm, 11.1kg
(Main Unit only)
Operation switches R ( + ) = Right rotation switch : Rotates the analyzer slowly to the right.
L ( - ) = Left rotation switch : Rotates the analyzer slowly to the left.
temp = Shift / Temp switch : Pressing this switch simultaneously with either ( + ) switch or the ( - ) switch will provide a faster rotation ( in the shift mode ).
* When this switch is pressed for 2 seconds or more, the temperature of the sample chamber is indicated on the display panel (until the switch is released from pressing).
Optional • Adapter for setting polarizer : RE-8766
Quartz control plate 34° : RE-72045
Quartz control plate 17° : RE-72044
Quartz control plate 8° : RE-72043
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Observation tube 100mm long OT-100 (P) : RE-6705
• Observation tube 200mm long OT-200 (P) : RE-6706
• Small volume tube 100mm long (OT-100M) : RE-6708
• Deck glass : RE-6712
• Rubber packing for observation tube : RE-6713
• Ring nut for observation tube : RE-6714
• Rubber packing for small volume tube : RE-6715
• Ring nut for small volume tube : RE-6717
• Midget fuse (1A) : RE-5784
  Catalog Download
Go to the product search GO TOP