Diese Inline-Modelle konnen in Rohrleitung von Produktionsanlagen, Mischvorrichtungen fur Flussigkeiten und Waschapparaten installiert werden, um die Konzentrationen verschiedener Flussigkeiten kontinuierlich zu messen. Sie sind fur den Einsatz bei Steuerungen von Misch-, Konzentrations-, Fermentierungsprozessen und der Kontrolle der Konzentration von wasserbasierten und alkalibasierten Reinigungsmitteln geeignet.

In-line Brix-Monitor CM-800α

This new addition to the CM series is compatible with the PRM-100α fittings.
Fittings are available in a wide variety of shapes and sizes.
The accuracy is ±0.1% across the entire range of 0-80% Brix.


Enlargement
Quantitat
SUS316L customizable PROFIBUS compatible VARIVENT compatible
>about the icons Can be connected to a recorder RS-232C Interface In-line measurement External temperature samples Continuous measurement High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V)
Model CM-800α Cat.No. 3564
Measurement Scale Brix (Automatic Temperature Compensation according to the sample liquid) [*1]
Measurement Range Brix 0.0 to 80.0% Minimum Indication Brix 0.01 or 0.1% (with an option to display measurements between 0.00 and 9.99% to the 2nd decimal place)
Measurement Accuracy Brix ±0.1% Measurement Temperature 5 to 100°C (Automatic Temperature Compensation)
Ambient Temperature 5 to 40°C Power Consumption 24VA
Output Rs-232C,DC 4 to 20mA Materials in contact with the Solution Prism : Sapphire
Prism stage : SUS316L
Power Supply DC24V
International Protection Class
IP67
Dust-tight and Protected against splashing water.
Dimensions & Weight 16×17×11cm, 2.4kg
(Main Unit only)
Accessory Power input cable (1m) [*2]
Optional * Calibration Certificate : Contact an ATAGO representative for details.
See below for other accessories.
See here for fitting options.
[*1] Contact ATAGO if you are interested in using the CM-800a to measure other types of solution.
[*2] The cable can be ordered to a custom length of up to 5m.
Go to the product search GO TOP

Kontinuierliches inline-Messsystem CM-800α-EG für Ethylenglykol

Das CM-800α-EG ist speziell entwickelt worden für die kontinuierliche inline-Messung von Ethylenglykol-Lösungen, die als Kühlmittel, Sole, Gefrierschutz- oder Enteisungsmittel eingesetzt werden.Das Gerät bietet darüber hinaus die Möglichkeit zur Anzeige des Gefrierpunkts der Lösung.


Enlargement
Quantitat
PROFIBUS compatible VARIVENT compatible
>PiktogrammerklärungCan be connected to a recorder RS-232C Interface In-line measurement External temperature samples Continuous measurement High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V)
Model CM-800α-EG Artikelnummer. 3531
Skalen Ethylenglykol (automatische Temperaturkompensation der Probenflüssigkeit) Meßbereich Ethylenglykol von 0.0 bis 90.0%
Gefrierpunkt von 0 bis -50℃ / 32 bis -60°F
Temperatur von 5 bis 100℃ / 41 bis 212°F
Minimaler Skalenwert Ethylenglykol 0.1%
Gefrierpunkt 1℃ / 1°F
Temperatur 1℃ / 1°F
Meßgenauigkeit Ethylenglykol ±0.4%
Gefrierpunkt ±1℃ / ±1°F
Temperatur ±1℃ / ±1°F
Mediumtemperatur von 5 bis 100℃
(automatische Temperaturkompensat)
Umgebungstemperatur von 5 bis 40°C
Signalausgang RS-232C ,
4 bis 20 mA
Materialien, die in Kontakt mit dem Meßmedium kommen Prisma : Saphir
Prisma Vorrichtung : : SUS316L
Spannungsversorgung 24 V DC
Internationale Schutzart
IP67
(staubfest und spritzwassergeschützt)
Maße und Gewicht 16×17×11cm, 2.4kg
(nur das Hauptgerät)
Optionen * Kalibrierzertifikat : Bei Bedarf kontaktieren Sie bitte eine Vertretung von ATAGO.
See below for other accessories.
See here for fitting options.
Zubehör Stromkabel (1m) [*1]
[*1] The cable can be ordered to a custom length of up to 5m.
Go to the product search GO TOP

In-line Monitor CM-800α-PG

The CM-800α-PG is specially designed for in-line concentration measurements of propylene glycol solutions used as coolants, brine, anti-freeze, and de-icing fluids. It also has a secondary scale for the freezing point.


Enlargement
Quantity
PROFIBUS compatible VARIVENT compatible
>about the iconsCan be connected to a recorder RS-232C Interface In-line measurement External temperature samples Continuous measurement High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V)
Model CM-800α-PG Cat.No. 3532
Measurement Scale P.G. (Automatic Temperature Compensation according to the sample liquid)
Freezing point
Temperature
Measurement Range P.G. 0.0 to 90.0%
Freezing point 0 to -50°C / 32 to -60°F
Temperature 5 to 100°C / 41 to 212°F
Resolution P.G. 0.1%
Freezing point 1℃ / 1°F
Temperature 1℃ / 1°F
Measurement Accuracy P.G. ±0.4%
Freezing point ±1℃ / ±1°F
Temperature ±1℃ / ±1°F
Measurement Temperature 5 to 100℃
(Automatic Temperature Compensation)
Ambient Temperature 5 to 40℃
Output RS-232C ,DC 4 to 20mA Materials in contact with the Solution Prism : Sapphire
Prism stage : SUS316L
Power Supply DC24V
International Protection Class
IP67
Dust-tight and Protected against splashing water.
Dimensions & Weight 16×17×11cm, 1.8kg
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
See below for other accessories.
Accessory Power input cable (1m) [*1]
Optional * Calibration Certificate : Contact an ATAGO representative for details.
See below for other accessories.
See here for fitting options.
[*1] The cable can be ordered to a custom length of up to 5m.
Go to the product search GO TOP

In-Line Refraktometer CM-800α-SW

This is an in-line refractometer for concentrations of sodium chloride in water (0.0-28.0%).
It is built to the same specifications as the original CM-800α with the Brix scale.


Enlargement
Quantity
PROFIBUS compatible VARIVENT compatible
>Piktogrammerklärung Can be connected to a recorder RS-232C Interface In-line measurement External temperature samples Continuous measurement High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V)
Modell CM-800α-SW Artikelnummer. 3533
Skalen Salzgehalt (automatischer Temperaturausgleich entsprechend der Probenflüssigkeit)
Meßbereich Salzgehalt
von 0.0 bis 28.0%
Temperatur
von 5 bis 100°C / 41 to 212°F
Minimaler Skalenwert Salzgehalt 0.01 or 0.1%
Temperatur 1°C
Meßgenauigkeit Salzgehalt ±0.1%
Temperatur ±1°C / ±2°C
Umgebungstemperatur von 5 bis 40°C
Mediumtemperatur von 5 bis 100°C (automatische Temperaturkompensation) Signalausgang (1) Recorder Ausgang :
4 bis 20 mA
(2) RS-232C Ausgang
Spannungsversorgung 24 V DC Materialien, die in Kontakt mit dem Meßmedium kommen Prisma : Saphir
Prisma Vorrichtung : SUS316L
Leistungsaufnahme 3VA
Internationale Schutzart
IP67 (staubfest und spritzwassergeschützt) Maße und Gewicht 16×17×11cm, 2.4kg
(nur das Hauptgerät)
Zubehör Stromkabel (1m) [*1]
Optionen * Kalibrierzertifikat : Bei Bedarf kontaktieren Sie bitte eine Vertretung von ATAGO. Weitere Optionen siehe unten.
See below for other accessories.
See here for fitting options.
[*1] The cable can be ordered to a custom length of up to 5m.
Go to the product search GO TOP

Optional

AC adapter Stand

Der AC Adapter wandelt Wechselspannungen von 100 - 240 V AC in 24 V Gleichspannung (DC) um und dient zur Spannungsversorgung für die Modelle CM-800α.


AD-32 (AC100V)
Artikelnr. 3527
AD-33 (AC110 to 120V)
Artikelnr. 3528
AD-34 (AC220 to 240V)
Artikelnr. 3529

Gestell zur Montage der Modelle CM-800αund dem AC Adapter.


RE-8607

Parts No. Names
RE-5635 Recorder output cable with 1 connector (5m)
RE-5636 Recorder output cable with 1 connector (10m)
RE-5638 Recorder output cable with 1 connector (15m)
RE-5639 Recorder output cable with 1 connector (20m)
RE-5677 RS-232C output cable with connector D-sub 25pin (15m)
RE-65330 RS-232C output cable with connector D-sub 9pin (15m)
RE-5647 RS-232C output cable with connector D-sub 25pin (Within 15m)
RE-65331 RS-232C Output Cable With Connector D-sub 9pin (Within 15m)
RE-8607 Stand (Stand for mounting the CM-800α and the AC adapter.)
Cat.No.3527 AC adapter AD-32 (AC100V)
Cat.No.3528 AC adapter AD-33 (AC110 to 120V)
Cat.No.3529 AC adapter AD-34 (AC220 to 240V)
GO TOP

In-Line Refraktometer CM-BASEα(A) / CM-BASEα(D)

Easy operation with only one cable for power supply and data output.Optimized for automation of real-time concentration monitoring.The CM-BASEα(A) transmits data via 4-20mA signals. The CM-BASEα(D) transmits data to a computer via RS-232C.


Enlargement
SUS316L customizable PROFIBUS compatible
>about the iconsCan be connected to a recorder RS-232C Interface In-line measurement External temperature samples Continuous measurement Calibration with water Digital display AC outlet (AC100 to 240V)
Model CM-BASEα(A) CM-BASEα(D)
Artikelnummer. 3603 3604
Preisanfrage
Quantitat
Quantitat
Meßbereich Brix 0.0 to 33.0%
Meßgenauigkeit Brix ±0.5%
Temperatur ±2.0°C
Mediumtemperatur von 10 bis 50°C
(automatische Temperaturkompensat)
Umgebungstemperatur von 10 bis 40°C
Signalausgang DC4 to 20mA RS-232C
Communications parameters - Baud rate : 2400bps
Partity : Even
Data length : 7bit
Stop bit : 1bit
Transmit data -

aa.a,bb.b(Brix, Temperature)
(Example) Brix =19.5%,
Temperature = 20.3°C ⇒
"19.5,20.3"

Internationale Schutzart
IP64
(staubfest und spritzwassergeschützt)
Maße und Gewicht 90×90×59mm, 820g (Main unit only)
Accessory Signal cable
(DC24V input, Recorder output)
2m [*1]
Signal cable
(DC24V input, RS-232C output)
2m [*2]
Optionen * Weitere Optionen siehe unten.
See here for fitting options.
[*1] The cable can be ordered to a custom length of up to 100m.
[*2] The cable can be ordered to a custom length of up to 15m.
Go to the product search GO TOP